PCB/Dioxin
damage remediation 
Project: "Remediation of a dioxin contaminated industrial chimney stack":
- Enclosure of the chimney flue and installation of air suction unit
with exhaust air filter and a black and white unit
- Removal of the soot deposits containing dioxin by a sand blasting process
- Vacuum extraction of dust containing dioxin caused during the removal
- Disposal of materials containing dioxin
Project: "Remediation of PCB contaminated rooms":
- Ventilation of plant parts by air exchanger with filters
- Isolation of secondary sources such as walls and ceilings with an
active charcoal wallpaper
- According to contamination, manual or mechanical removal of jointing material
containg PCB with continuous extraction from the working area
|
|
|